Skip to main content

Continuous Representations and Physics-Guided Reconstruction

From discrete measurements to continuous images

An implicit neural representation (INR) maps coordinates to image intensities or spatial features through a function $f_\theta: \mathbb{R}^d \rightarrow \mathbb{R}^n$. This supports querying different sampling grids and incorporating the forward imaging model into optimization. A continuous representation does not imply unlimited recoverable detail: the available measurements, priors, and modeling assumptions still determine what can be reconstructed.

1. Diffusion priors and data consistency

Generative priors can help resolve information missing from undersampled measurements, but they must remain constrained by observations. We study this interaction through both optimization design and the diffusion sampling process.

  • DC-PnPDP (ICML 2026): Uses ADMM dual variables to carry mismatch information between data consistency and the diffusion prior across iterations. Spectral homogenization adapts structured residuals for the denoiser, improving their coupling in CT and MRI inverse problems.

  • ISCS (ICLR 2026): Coordinates stochastic noise components across slices during diffusion sampling, improving volumetric consistency when using pretrained 2D priors without training a new 3D model.

  • DPER (arXiv, 2024) and DiffINR (Medical Image Analysis) combine diffusion priors with INR reconstruction for limited-angle/sparse-view CT and accelerated MRI, respectively.

2. Scan-specific reconstruction and arbitrary-scale representation

  • SCOPE (IEEE TCI): Combines a continuous image representation with the projection model for self-supervised sparse-view CT reconstruction.

  • Spener (AAAI 2025): Embeds a self-prior in iterative sparse-view CT reconstruction to exploit structure within the data being reconstructed.

  • Scan-specific parallel MRI (IEEE ISBI 2023): Uses scan-specific INR optimization for unsupervised parallel MRI reconstruction without paired training data.

  • IREM (MICCAI 2021): Studies high-resolution MRI reconstruction using a continuous neural representation.

  • ArSSR (IEEE J-BHI): Supports arbitrary-scale 3D MRI super-resolution through coordinate queries rather than a separate model for each upsampling factor.

  • Anisotropic MRI super-resolution (IEEE ISBI 2023): Studies arbitrary-scale reconstruction of anisotropic MRI using self-supervision.

3. Motion correction and dynamic reconstruction

Treating motion as part of image formation, rather than only correcting it after reconstruction, enables joint estimation of images, motion, and acquisition parameters.

  • Moner (ICLR 2025): Uses an unsupervised neural representation for motion correction and reconstruction in undersampled radial MRI.

  • JSMoCo (Medical Image Analysis): Uses a self-calibrating score-based diffusion model to jointly address coil sensitivity estimation and motion correction in parallel MRI.

  • MoCo-INR (AAAI 2026): Combines motion-compensated decomposition with neural representation for unsupervised cardiac MRI reconstruction.

  • Self-calibrating CT neural field (IEEE ISBI 2023): Jointly estimates rigid motion and image reconstruction in sparse-view CT using a self-calibrating neural field.

4. Artifact reduction through physical modeling

  • Diner (IEEE TRPMS): Represents an energy-independent density field and incorporates polychromatic X-ray image formation to address CT metal artifacts.

  • Polyner (NeurIPS 2023): Incorporates polychromatic X-ray modeling into an unsupervised neural representation to address metal-induced attenuation effects and artifacts.

  • Riner (AAAI 2026): Uses joint multi-parameter inverse solving to reduce ring artifacts in 3D cone-beam CT.

5. Anatomy and field reconstruction from sparse views

  • ALFA (MICCAI 2026): First learns a shared continuous anatomical latent space from CT, then optimizes a subject’s latent code under the acquisition geometry to match biplanar X-rays. Separating anatomical representation from geometry adaptation supports reconstruction across acquisition setups without retraining the decoder.

  • Biplanar knee CT reconstruction (IEEE ISBI 2024): Estimates 3D knee anatomy from two X-ray projections using a self-supervised neural field.

  • 3D thermometry reconstruction (ISBI 2025): Integrates tri-planar images through a cross-view implicit representation for accelerated 3D thermometry field reconstruction.

6. Algorithm–hardware co-design

Computational cost matters alongside reconstruction quality. We also study hardware implementations and computational pipelines for neural representations.

  • RTSyner (IEEE TNNLS): Studies real-time neural representation for sparse-view CT through algorithm–hardware co-design.

  • Energy-efficient INR accelerator (IEEE TCAS-I): Develops dedicated acceleration for medical image reconstruction from implicit neural representations.